Categories

ATEX Temperature Probes

Atex Temperature Probes Certificated for risk areas where needs to acquire measures in complete safety


Pt100 Atex
Model ASPT-H-Ex

Pt100 Atex

  • Atex Thermometric complex
  • RTD Pt100 Atex ohm @ 0 °C, Tmax: °C
  • Simple/double execution
  • Number of wires: 2/3/4
  • Tolerance class: B, A, 1/3 DIN
  • Sheath Diameter: from 3 to 21 mm
  • Sheath Material : Stainless Steel 304, 310, 316, 321
  • Simple or Oxide Mineral compressed (MgO) insulation
  • Sheath lenght: on request
  • Terminal Connection Head: Ex d Atex – Tamb [-40 °C to + 60 °C]
  • Connection by ceramic terminal block or Atex transmitter outpu 4/20 mA 4/20 mA – Tamb [-25 °C to + 40 °C]
  • Fix or sliding compression fittings in Stainless Steel

The ATEX thermometric complex will be compliance with the essential health and safety requirement established from the attached II of Directive 94/9/EC (ATEX) which has been subjected to a conformity assessment procedure for the categories 1G 1/2D with the following ATEX marking string:

1G Ex d ia IIC TX X
II 1/2 D Ex tD A20/21 IP6X (XXX)°C X

Atex production quality assurance certificate number: DNV-MUNO 08 ATEX 3751 Q


Thermocouple Atex
Model ASTC-H-Ex

Thermocouple Atex

  • Atex Thermometric complex
  • Thermocouple ATEX
  • Single or Double thermocouple
  • B,R,S,K,J,E,T,N Type
  • Tmax: °C
  • Hot Joint: Isolated, grounded, exposed
  • Class: Special or Standard IEC584
  • Sheath diameter: from 0,5mm to 21mm
  • Sheath Material: Stainless Steel 304, 310, 316, 321, Inconel 600
  • Simple or Oxide Mineral (MgO) Insulation
  • Sheath lenght: on request
  • Terminal Head Connection: Ex d Atex case – Tamb [-40 °C to + 60 °C]
  • Connection by ceramic terminal block or Atex transmitter output 4/20 mA 4/20 mA – Tamb [-25 °C to + 40 °C]
  • Fix or sliding compression fittings in Stainless Steel

The ATEX thermometric complex will be compliance with the essential health and safety requirement established from the attached II of Directive 94/9/EC (ATEX) which has been subjected to a conformity assessment procedure for the categories 1G 1/2D with the following ATEX marking string:

II 1G Ex d ia IIC TX X
II 1/2 D Ex tD A20/21 IP6X (XXX)°C X

Atex production quality assurance certificate number: DNV-MUNO 08 ATEX 3751 Q


High Temperature ATEX Thermocouple
Model ASTC-G-Ex

High Temperature Atex Thermocouple

  • Atex Thermometric complex
  • Thermocouple ATEX high temperature
  • Single or Double thermocouple
  • B,R,S,K,J,E,T,N Type
  • Tmax: °C
  • Hot Joint: Isolated
  • Class: Special or Standard IEC584
  • Ceramic Sheath diameter: from 4mm to 26mm
  • Ceramic Sheath Material: Ker 610, Ker 799
  • Insulation: simple by two-bores/four-bores or Oxide Mineral compressed (MgO)
  • Sheath lenght: on request
  • Sleeve in Stainless Steel
  • Sleeve lenght: on request
  • Terminal Head Connection: Ex d Atex case – Tamb [-40 °C to + 60 °C]
  • Connection by ceramic terminal block or Atex transmitter output 4/20 mA 4/20 mA – Tamb [-25 °C to + 40 °C]
  • Fix or sliding compression fittings in Stainless Steel

The ATEX thermometric complex will be compliance with the essential health and safety requirement established from the attached II of Directive 94/9/EC (ATEX) which has been subjected to a conformity assessment procedure for the categories 1G 1/2D with the following ATEX marking string:

II 1G Ex d ia IIC TX X
II 1/2 D Ex tD A20/21 IP6X (XXX)°C X

Atex production quality assurance certificate number: DNV-MUNO 08 ATEX 3751 Q


Atex Thermowell
Model ASPZ-Ex

Atex Thermowell

  • Tube / Rod Thermowell
  • Sheath in Stainless Steel 304,310,316,446, Inconel 600
  • External diameter: as your required (minimum thickness 3mm compared with inner hole)
  • Inner hole: as your required
  • Process joint: thread Gas, NPT (fix or sliding) or flanged
  • Thermosensor connection: threaded Gas or NPT
  • Lenght under process joint: as your required
  • Cylindrical/conical execution
  • Max pressure: depending on process

Atex Temperature signal Transmitter
Model 205X

Atex Transmitter

Smart Temperature Transmitter second-generation for head sensor mounting.

It receive the input signal from temperature sensor turning the output into a standard industrial signal (4/20 mA)

SEM205X is EC Certificated confirming the compliance of European Atex for: Intrinsic Safety II 1 G EEx ia IIC T4…T6


Atex Temperature signal Transmitter
Model 210X

Atex Transmitter

Smart Temperature Transmitter second-generation for head sensor mounting.

It receive the input signal from temperature sensor, potentiometers and millivolt signal turning the output into a standard industrial signal (4/20 mA)

SEM 210X is configurable with PC and it’s EC Certificated confirming the compliance of European Atex for: Intrinsic Safety II 1 G EEx ia IIC T4…T6


Atex Hart Protocol Temperature Signal Transmitter
Model 310X

Atex Transmitter

Smart Temperature Transmitter with HART Protocol for head sensor mounting. It receive the input signal from temperature sensor, potentiometers and millivolt signal turning the output into a standard industrial signal (4/20 mA).

The SEM 310X can be programed by M-CONFIG software or by HART comunicator equipped with the “Device Description”.

The M-CONFIG software isa equipped with istruction to configure the transmitter.

SEM 310X is EC Certificated confirming the compliance of European Atex for:

Intrinsic Safety II 1 G EEx ia IIC T4…T6
Energy Limits II 3 G EEx Nl IIC

Newsletter